Today we are at the beginning of a new era, named ‘Industrie 4.0’. Let´s explain a little further the concept "Industrie 4.0"!
AEL-AD3A Fortgeschrittene Anwendung von Feueralarmen
INNOVATIVE SYSTEME
The Fire Alarm Application, "AEL-AD3A", is designed with the aim to study different types of fire alarms.
Erweiterungen
ÄHNLICHE NEUIGKEITEN
ALLGEMEINE BESCHREIBUNG
The Fire Alarm Advanced Application, "AEL-AD3A", is designed with the aim to study different types of fire alarms. This complete application includes several types of sensors and alarms.
The sensors included are a smoke detector, an ionized air detector and a temperature detector. These sensors activate the following alarms, also included: indoor siren, bell type alarm and a water solenoid valve to extinguish the fire.
All these devices are controlled by a fire alarm station with battery, just in case the fire damages the electrical system. This application will be used by students to simulate several situations caused by fires and study the operation of each device.
ÜBUNGEN UND GEFÜHRTE PRAKTIKEN
GEFÜHRTE PRAKTISCHE ÜBUNGEN IM HANDBUCH ENTHALTEN
- Checking and measuring the main power supply.
- Checking the working of the auxiliary power supply.
- Checking the operation and control of the Fire Alarm Station.
- Simulate situations in two safety zones managed by the Fire Alarm Station.
- Checking the operation of the air ionization sensor.
- Checking the operation of the temperature sensor.
- Checking the operation of the smoke detector.
- Checking the operation of the indoor siren.
- Checking the operation of the bell.
- Checking the operation of the water solenoid valve.
- Combine the different types of sensors with the alarms to simulate different situations.
ÄHNLICHE VERFÜGBARE GERÄTE
4.2.1.- KONVENTIONELLE ANWENDUNGEN
AEL-AD3B
The Fire Alarm Application, "AEL-AD3B", is designed with the aim to study different types of fire alarms. This application includes several types of sensors and one alarm. The sensors included are a smoke detector and an ionized air detector.These...
ERGÄNZENDE AUSRÜSTUNG
4.2.1.- KONVENTIONELLE ANWENDUNGEN
AEL-AD1A
Fortgeschrittene Anwendung der Alarmanlage gegen Diebstahl
The Robbery Alarm Advanced Application, "AEL-AD1A", is designed with the aim to show different burglar alarms to the students. This application is composed of the next types of sensors: glass break detector and motion sensors.The application also...
4.2.1.- KONVENTIONELLE ANWENDUNGEN
AEL-AD1B
Anwendung der Alarmanlage gegen Diebstahl
The Robbery Alarm Application, "AEL-AD1B", is designed with the aim to show different burglar alarms to the students. This application is composed of the next types of sensors: glass break detector and motion sensors. The application also includes...
4.2.1.- KONVENTIONELLE ANWENDUNGEN
AEL-AD3B
Anwendung von Feueralarmen
The Fire Alarm Application, "AEL-AD3B", is designed with the aim to study different types of fire alarms. This application includes several types of sensors and one alarm. The sensors included are a smoke detector and an ionized air detector.These...
4.2.1.- KONVENTIONELLE ANWENDUNGEN
AEL-AD15A
Fortgeschrittene Anwendung der Positionssteuerung
The Position Control Advanced Application, "AEL-AD15A", has been designed by EDIBON to study different types of position sensors and their possible applications.For that purpose, this application includes the following sensors:A PNP type inductive...
4.2.1.- KONVENTIONELLE ANWENDUNGEN
AEL-AD15B
Anwendung der Positionssteuerung
The Position Control Application, "AEL-AD15B", has been designed by EDIBON to study different types of position sensors and their possible applications. For that propose, this application includes the following sensors:A PNP type inductive sensor...
4.2.1.- KONVENTIONELLE ANWENDUNGEN
AEL-AD25A
Kontrollsystem für häusliche Elektrodienste über Telefon
The Control Application for Home Electric Services through the Telephone, "AEL-AD25A", has been designed by EDIBON to study some home safety applications. This system includes the most common ones, such as the flooding control, gas leakage...
4.2.1.- KONVENTIONELLE ANWENDUNGEN
AEL-AD22
Anwendung der Flutsteuerung
The Flooding Control Aplication, "AEL-AD22", has been designed by EDIBON to know and study the operation of the most common flooding control systems.This application has two parts:On one side, there is a water tank divided into two parts: one to...
4.2.1.- KONVENTIONELLE ANWENDUNGEN
AEL-AD30
Anwendung der Gas- und Raucherkennung
The Gas and Smoke Detection Application, "AEL-AD30", has been designed by EDIBON to study the operation of a gas leak detection and fire prevention system. This application includes two types of sensors. On one hand, there is a gas detector...
4.2.1.- KONVENTIONELLE ANWENDUNGEN
AEL-AD31
Anwendung der Bewegungs- und Geräuscherkennung
The Movement and Sound Detection Application, "AEL-AD31", is an application designed to understand the operation of the most common intrusion detector. The intrusion detector of this application consists of a device made up of magnets, which can...
4.2.1.- KONVENTIONELLE ANWENDUNGEN
AEL-AD40
Anwendung von Fernsteuerung via Telefon
The Remote Control Application Via Telephone, "AEL-AD40", is designed to study the operation of a remote control system via telephone, in other words, for the remote control of sensors, alarms, etc. installed in a house, office, etc. With this...