TIPLA Penukar Panas Pelat yang Diperluas untuk TICC

EXTENDED PLATE HEAT EXCHANGER FOR TICC - TIPLA

SISTEM INOVATIF

The Expanded Plate Heat Exchanger for TICC, "TIPLA", designed by EDIBON, enables detailed study of heat transfer between hot and cold water flowing through alternate channels formed between parallel plates.

Lihat uraian umum

BERITA TERKAIT

GAMBARAN UMUM

The Expanded Plate Heat Exchanger for TICC, "TIPLA", designed by EDIBON, enables detailed study of heat transfer between hot and cold water flowing through alternate channels formed between parallel plates.

This unit facilitates analysis of heat transfer variation under different conditions such as changes in flow rate, temperature, and flow type (counterflow or parallel). With a plate arrangement optimized for enhanced heat transfer, the Expanded Plate Heat Exchanger for TICC offers an effective tool for heat exchange analysis and experimentation. Moreover, it allows for temperature measurement between the plates, which is essential for ensuring efficient thermal exchange and detecting potential issues. This capability enables monitoring of the exchanger’s efficiency, identification of system faults, optimization of design, and understanding of thermal distribution within the unit.

These detailed measurements facilitate adjustments to the exchanger’s operation to enhance performance and ensure proper heat flow between circulating fluids.

In summary, the Expanded Plate Heat Exchanger for TICC, "TIPLA", provides students, professors, and researchers with an opportunity to deeply understand and apply fundamental principles of heat transfer in plate exchangers. Thanks to its innovative design of parallel plates, this unit enables detailed and applicable insights in the industry.

To work with this unit, the Base and Service Unit, "TIUS", is required, which provides key functions such as heating water using a thermostatic bath, pumping hot water, regulating and measuring the flow rates of cold and hot water, measuring the inlet and outlet temperatures of cold and hot water, as well as measuring the pressure drop in the heat exchanger.

LATIHAN DAN PRAKTEK PEDOMAN

LATIHAN PRAKTIS YANG DIANDAL TERMASUK DALAM PANDUAN

  1. Global energy balance in the heat exchanger and the study of losses.
  2. Exchanger effectiveness determination. NTU Method.
  3. Study of the heat transfer under counter-current and co-current flow conditions.
  4. Flow influence on the heat transfer. Reynolds number calculation.
  5. Sensors calibration.

LEBIH BANYAK LATIHAN PRAKTIS YANG AKAN DILAKUKAN DENGAN UNIT

  1. Study of the hysteresis of the flow sensor.

Other possibilities to be done with this unit:

  1. Many students view results simultaneously. To view all results in real time in the classroom by means of a projector or an electronic whiteboard.
  2. Open Control, Multicontrol and Real Time Control. This unit allows intrinsically and/or extrinsically to change the span, gains, proportional, integral, derivative parameters, etc, in real time.
  3. The Computer Control System with SCADA and PID Control allow a real industrial simulation.
  4. This unit is totally safe as uses mechanical, electrical/electronic, and software safety devices.
  5. This unit can be used for doing applied research.
  6. This unit can be used for giving training courses to Industries even to other Technical Education Institutions.
  7. Control of the unit process through the control interface box without the computer.
  8. Visualization of all the sensors values used in the unit process.
  9. By using PLC-PI additional 19 more exercises can be done.
  10. Several other exercises can be done and designed by the user

BARANG YANG DIBUTUHKAN

PERALATAN SIMILAR TERSEDIA

KUALITAS

LAYANAN PURNA JUAL

Meminta informasi