The Three-phase Installations Faults Application, "AEL-AD33T", has been designed by EDIBON to study certain protections used in industrial installations.
Laboratorium
BERITA TERKAIT
GAMBARAN UMUM
The Three-phase Installations Faults Application, "AEL-AD33T", has been designed by EDIBON to study certain protections used in industrial installations. Using safety elements, students can simulate different faults and verify the reasons why each type of protection acts. This includes some innovative electrical devices for protecting people and installations against the effects of electrical current. These devices ensure the continuity of power availability as well as the safety of people. This application includes a three-phase transformer to simulate ground faults under safe conditions.
It is also possible to change the configuration of ground connection of the charges connected to the system. Some of those configurations are: TN, IT, TN-S, TN-C, TN-C-S.
The protections included are: three-phase differential protection, three-phase differential protection with automatic reset, and three-phase differential protection with variable sensitivity. To check all protections, a variable resistor is included to control current shunts. It also includes meters to determine the magnitude of the current shunt and verify the sensitivity of the protection.
LATIHAN DAN PRAKTEK PEDOMAN
LATIHAN PRAKTIS YANG DIANDAL TERMASUK DALAM PANDUAN
- Study of basic concepts of three-phase differential protection.
- Study of three-phase differential protection with variable sensitivity.
- Study of three-phase differential protection with automatic restore.
- Adjustment of sensibility of the three-phase differential protection.
- Study of short-circuits in three-phase system with basic differential protection.
- Study of short-circuits in three-phase system with short-circuit impedance and basic differential protection.
- Study short-circuits in three-phase system with differential protection with variable sensitivity.
- Study short-circuits in three-phase system with short-circuit impedance and differential protection with variable sensitivity.
- Study short-circuits in three-phase system with differential protection with automatic restore.
- Study short-circuits in three-phase system with short-circuit impedance and differential protection with automatic restore.
- Study of isolation coordination.
- Checking the differences between some different grid system configurations in the face of disturbances.