Today we are at the beginning of a new era, named ‘Industrie 4.0’. Let´s explain a little further the concept "Industrie 4.0"!
AEL-AE9 Power Flux Protection Application
INNOVATIVE SYSTEME
The Power Flux Protection Application, “AEL-AE9”, has been designed to study the protection devices that deal with the resolution of network events involving reverse power flow and power factor alteration.
Erweiterungen
ÄHNLICHE NEUIGKEITEN
ALLGEMEINE BESCHREIBUNG
The Power Flux Protection Application, “AEL-AE9”, has been designed to study the protection devices that deal with the resolution of network events involving reverse power flow and power factor alteration. This application allows the user to understand the operation of the protection devices during power factor detection below established limits and detection of a reverse power flow, as well as the incidents that may be caused.
The “AEL-AE9” application consists of a power factor protection relay and a reverse power flow protection relay, with their correspondent power switch, to study the operation of these protection devices when these circumstances are detected in the grid. Two squirrel-cage three-phase asynchronous motors are also included to produce a reverse power flow, creating the circumstances to study the protection devices operation.
One of the motor works as prime mover and it is controlled by a frequency controller. The second motor works as an electricity generator and it is coupled to the prime mover. Analog meters are included too to study the operation of the electrical machines. Additionally it is included a network analyzer which displays all the parameters involved in the grid. Finally, this application includes resistive, inductive and capacitive loads that cause different consumption conditions for the study of the influence of each one on the power factor, and the response of the correspondent protection devices.
ÜBUNGEN UND GEFÜHRTE PRAKTIKEN
GEFÜHRTE PRAKTISCHE ÜBUNGEN IM HANDBUCH ENTHALTEN
- Study of the starting of an asynchronous electric machine with starting capacitor.
- Manual regulation of the speed of an asynchronous electric machine to generate an over-slip and cause an inverse power flow. Operation both in generator mode and in motor mode.
- Analysis of active and reactive power and their influence on the operation of the protection relays to provoke a response from them.
- Setting of the Reverse Power protection.
- Testing of the reverse power protection response to a reverse power flow.
- Setting of the Power Factor protection.
- Testing of the power factor protection response to below established limits power factor.
- Calculation of the power factor when there is a resistive load variation and consequent response of the power factor protection.
- Calculation of the power factor when there is an inductive load variation and consequent response of the power factor protection.
- Calculation of the power factor when there is a capacitive load variation and consequent response of the power factor protection.
ÄHNLICHE VERFÜGBARE GERÄTE
4.1.2.2.- ELEKTRISCHE RISIKEN UND SCHUTZ
AEL-AE5
The Protection Relays Control Application, "AEL-AE5", is designed with the aim to understand the working of protection relays. This application is formed by the next kind of relays: over current relays, which open the circuit when it detects a...
ERGÄNZENDE AUSRÜSTUNG
4.1.2.2.- ELEKTRISCHE RISIKEN UND SCHUTZ
AEL-AD33
Single-Phase Installations Faults Application
In a low-voltage electrical system, one of the objects to study are single-phase faults. When a single-phase fault happens, it affects at the rest of the electric system because it produces a very increase current which also affects the voltages...
4.1.2.2.- ELEKTRISCHE RISIKEN UND SCHUTZ
AEL-AD33T
Three-phase Installations Faults Application
The Three-phase Installations Faults Application, "AEL-AD33T", has been designed to study several protections belonging to industrial installations. Through safety elements, the students can simulate different faults and verify the reasons why...
4.1.2.2.- ELEKTRISCHE RISIKEN UND SCHUTZ
AEL-AI11
People safety against indirect electrical contacts in IT neutral regimen
4.1.2.2.- ELEKTRISCHE RISIKEN UND SCHUTZ
AEL-AE5
Protection Relays Control Application
The Protection Relays Control Application, "AEL-AE5", is designed with the aim to understand the working of protection relays. This application is formed by the next kind of relays: over current relays, which open the circuit when it detects a...
4.1.2.2.- ELEKTRISCHE RISIKEN UND SCHUTZ
AEL-PMEI
Protection Measures in Electrical Installations
The Protection Measures in Electrical Installations, "AEL-PMEI", has been designed by EDIBON for training practical and professional level in the field of installation and testing of the main electrical protections for the housing and industry and...
QUALITÄT

KUNDENDIENST